oscilloscope (X-Y)

also called "vectorscope", this is similar to the normal oscilloscope in that it draws audio output as a waveform, but instead of being one-dimensional and going from left to right, it is plotted in two dimensions (usually X represents left output and Y represents right output).

(TODO: image)

right-clicking the X-Y oscilloscope window displays settings:

  • X Channel: the output channel which will affect the X (left-right) axis. 1 is left.
    • Invert: flips the axis.
  • Y Channel: the output channel which will affect the Y (up-down) axis. 2 is right.
    • Invert: flips the axis.
  • Zoom: changes amplitude, making the plot bigger or smaller.
  • Samples: the maximum number of samples to use for plotting.
    • this setting may be replaced by another or removed in a future version.
  • Decay Time (ms): sets how long it takes for the points/lines to fade away.
  • Intensity: changes the brightness of the dots/lines.
  • Line Thickness: sets how thick lines are.