fix absorb instrument bug: octave set to -1 when most recent 'note' was OFF/REL/===
This commit is contained in:
parent
08143a54ae
commit
aeee6260ae
|
@ -1846,8 +1846,11 @@ void FurnaceGUI::doAbsorbInstrument() {
|
|||
}
|
||||
|
||||
// absorb most recent octave (i.e. set curOctave such that the "main row" (QWERTY) of
|
||||
// notes will result in an octave number equal to the previous note).
|
||||
if (!foundOctave && pat->data[i][0] != 0) {
|
||||
// notes will result in an octave number equal to the previous note). make sure to
|
||||
// skip "special note values" like OFF/REL/=== and "none", since there won't be valid
|
||||
// octave values
|
||||
unsigned char note=pat->data[i][0];
|
||||
if (!foundOctave && note!=0 && note!=100 && note!=101 && note!=102) {
|
||||
foundOctave=true;
|
||||
|
||||
// decode octave data (was signed cast to unsigned char)
|
||||
|
|